There is no constraint about idProduct in USB spec. So, pids[i] may be 0 for USB devices.
Change-Id: I19d8974f4e7082e8b7e1f2d33c019ac4e61bc1e2
Signed-off-by: Hsiangkai Wang <hsiangkai@gmail.com>
Reviewed-on: http://openocd.zylin.com/1091
Tested-by: jenkins
Reviewed-by: Xiaofan <xiaofanc@gmail.com>
Reviewed-by: Freddie Chopin <freddie.chopin@gmail.com>
The makes sure the DWT component is always enabled so that watchpoints
work as expected.
This does need merging into the existing cortex_m logic, however at the
moment this is non trivial.
Change-Id: Ic6cccd1badb51f70a2ca8ea9ab6923788a94c1bf
Signed-off-by: Spencer Oliver <spen@spen-soft.co.uk>
Reviewed-on: http://openocd.zylin.com/1122
Tested-by: jenkins
Reviewed-by: Freddie Chopin <freddie.chopin@gmail.com>
An issue has been seen with the stm32lx flash driver that if a
power cycle/reset is applied after a erase, any ram loader will Hard Fault
on execution.
A similar issue is mentioned in the errata for the device.
Two solution's seem to workaround this issue:
1, Handle the exception, this means adding exception vectors to the loader
and changing the exception address using nvic vtor register.
2. falling back to using slower direct page writes - approx 50% slower.
Using solution 1 would mean restrictions are placed on the loader location.
Solution 2 was chosen mainly as it was simpler too implement.
Change-Id: I429f06b5a3e3b1d8de90071a88a7df11fc9b46a7
Signed-off-by: Spencer Oliver <spen@spen-soft.co.uk>
Reviewed-on: http://openocd.zylin.com/1010
Tested-by: jenkins
Waiting 20secs is a bit much excessive, we could probably reduce to 5.
Change-Id: Iffb97adb99c2541a075fe78dbc88a53ddf340214
Signed-off-by: Spencer Oliver <spen@spen-soft.co.uk>
Reviewed-on: http://openocd.zylin.com/1009
Tested-by: jenkins
Handle any leading bytes upto the next 128 byte page, enabling us to safely
use the faster page write.
Rather than use a separate word/byte write to program any trailing bytes
we use a combined write function.
Use memcpy for byte writes and change loader to using bytes.
Change-Id: Ie0164a30388f018dd00e752cf5ff87d4f96ced97
Signed-off-by: Spencer Oliver <spen@spen-soft.co.uk>
Reviewed-on: http://openocd.zylin.com/1008
Tested-by: jenkins
As we use the two ST flash drivers for multiple stm32 variants update the
docs as to which targets use which driver.
Change-Id: I84943ff45482a22b3d3dd8491bb4242d79415939
Signed-off-by: Spencer Oliver <spen@spen-soft.co.uk>
Reviewed-on: http://openocd.zylin.com/990
Tested-by: jenkins
Reviewed-by: Andreas Fritiofson <andreas.fritiofson@gmail.com>
automake-1.13 has now deprecated AM_CONFIG_HEADER, use the correct
AC_CONFIG_HEADERS instead.
Change-Id: I8adaec64cbad7f7318ff69091176c30b707cbb0b
Signed-off-by: Spencer Oliver <spen@spen-soft.co.uk>
Reviewed-on: http://openocd.zylin.com/1117
Tested-by: jenkins
Reviewed-by: Mikko Viitamäki <mikko.viitamaki@gmail.com>
Reviewed-by: Freddie Chopin <freddie.chopin@gmail.com>
Fixed flash page size detection according to EFM32 GG/LG errata.
MEM_INFO_PAGE_SIZE register containts invalid value in devices with
revision number lower than 18 and should not be used.
Change-Id: Idb2832246efcbbec2fd98a5c458f72a36df386fb
Signed-off-by: Roman D <me@iamroman.org>
Reviewed-on: http://openocd.zylin.com/1116
Tested-by: jenkins
Reviewed-by: Spencer Oliver <spen@spen-soft.co.uk>
When current tap state and end state are the same, transitions are added which is not what should happen.
The usbprog driver was already patched like this long time ago.
Change-Id: I339e87156bdc7b5c83c10c14025b749605d3871a
Signed-off-by: Roman Reichel <romanreichel@aol.de>
Reviewed-on: http://openocd.zylin.com/1113
Tested-by: jenkins
Reviewed-by: Spencer Oliver <spen@spen-soft.co.uk>
Limited (no page unprotect, no block writes) implementation of EFM32
flash support. Verified with EFM32 development kit and STLink V2 adapter
using SWD.
Change-Id: I3db2054d9aa628a1fe4814430425db3c9959c71c
Signed-off-by: Roman D <me@iamroman.org>
Reviewed-on: http://openocd.zylin.com/1106
Tested-by: jenkins
Reviewed-by: Spencer Oliver <spen@spen-soft.co.uk>
This is only minimal support to enable use to catch a Hard Fault in
the stm32l flash bootloader.
Change-Id: I21d6a11893e2f1d173ebff1a651d6f52bf6eec32
Signed-off-by: Spencer Oliver <spen@spen-soft.co.uk>
Reviewed-on: http://openocd.zylin.com/1103
Reviewed-by: Peter Stuge <peter@stuge.se>
Tested-by: jenkins
Currently we have to supply the arg's to this cmd in a set order, this
change fixes that issue.
Change-Id: I14a15732e1917a91009e1ac14fba39ca1523c739
Signed-off-by: Spencer Oliver <spen@spen-soft.co.uk>
Reviewed-on: http://openocd.zylin.com/992
Tested-by: jenkins
Reviewed-by: Andreas Fritiofson <andreas.fritiofson@gmail.com>
Make sure we do not mask out the BFB2 boot bank bit, as this is used on
the larger XL devices.
Change-Id: Iacfdf874140e409e0c4ca9b9aee8f5c2f90dc9be
Signed-off-by: Spencer Oliver <spen@spen-soft.co.uk>
Reviewed-on: http://openocd.zylin.com/991
Tested-by: jenkins
Reviewed-by: Andreas Fritiofson <andreas.fritiofson@gmail.com>
The STM32F0 and F3 devices use a different default RDP to configure a
unlocked device, make sure we use that.
Change-Id: I170779461412c4c202c2cfc8d90baedb7e388150
Signed-off-by: Spencer Oliver <spen@spen-soft.co.uk>
Reviewed-on: http://openocd.zylin.com/984
Tested-by: jenkins
Reviewed-by: Andreas Fritiofson <andreas.fritiofson@gmail.com>
The user is able to use 2bytes of the options byte data for whatever
purpose they wish. Make sure we preserve this during an option erase/write.
Change-Id: Ibf951b11c59a148e671b1eb47fdc9b4f49ccae15
Signed-off-by: Spencer Oliver <spen@spen-soft.co.uk>
Reviewed-on: http://openocd.zylin.com/983
Tested-by: jenkins
Reviewed-by: Andreas Fritiofson <andreas.fritiofson@gmail.com>
Some debuggers (stlink) can't issue 16 bit writes and have to use a
loader to write flash memory.
Currently the loader is not used for option bytes, causing
stm32x_write_options to fail silently on such hardware.
Fix this by using stm32x_write_block to write option bytes as well.
Change-Id: I49c29d53ab5e162463cb349d4c89bef96467e587
Signed-off-by: Szymon Modzelewski <szmodzelewski@gmail.com>
Reviewed-on: http://openocd.zylin.com/480
Tested-by: jenkins
Reviewed-by: Andreas Fritiofson <andreas.fritiofson@gmail.com>
The current stm32lx driver will fail if no working area is
provided - fallback to using slow writes if this is the case.
Change-Id: I92b1535fec4aebc855c63ce2c54b10f168f3c07e
Signed-off-by: Spencer Oliver <spen@spen-soft.co.uk>
Reviewed-on: http://openocd.zylin.com/1007
Tested-by: jenkins
Reviewed-by: Andreas Fritiofson <andreas.fritiofson@gmail.com>
This part has 16k ram so make it all available.
Change-Id: Ifeb7bc850bfe4f68d0affb8f6a0931b4327e7257
Signed-off-by: Spencer Oliver <spen@spen-soft.co.uk>
Reviewed-on: http://openocd.zylin.com/1006
Tested-by: jenkins
Reviewed-by: Andreas Fritiofson <andreas.fritiofson@gmail.com>
The smallest pert in the family has 10k RAM, so use that as a default
for the working area.
Change-Id: I78be0d14a254c109ac15a7163552c6132f810416
Signed-off-by: Spencer Oliver <spen@spen-soft.co.uk>
Reviewed-on: http://openocd.zylin.com/1005
Tested-by: jenkins
Reviewed-by: Andreas Fritiofson <andreas.fritiofson@gmail.com>
Switch to using the internal HSI when a reset init is called, this also
matches the std stm32l cfg.
Read (verify) speed is increased from 17 to 120 KiB/s.
Change-Id: Ic94ba85949ffdefa17b7be45eef14e30f941d107
Signed-off-by: Spencer Oliver <spen@spen-soft.co.uk>
Reviewed-on: http://openocd.zylin.com/1004
Tested-by: jenkins
Reviewed-by: Andreas Fritiofson <andreas.fritiofson@gmail.com>
The stlink/v2 has the ability to check the target voltage if the firmware
is recent enough (>= J13).
As a debugging aid we check the voltage at startup and issue an error if
this is too low to debug reliably.
Change-Id: I98e251f3880e31049c4307051c30bedd3451cf87
Signed-off-by: Spencer Oliver <spen@spen-soft.co.uk>
Reviewed-on: http://openocd.zylin.com/980
Tested-by: jenkins
Reducing the select and MsgWaitForMultipleObjects timeouts to 1ms makes
a 2-300+% increase in the step time of gdb when using pipes under windows OS.
Change-Id: Id7e52cfb2b206347a9caea61672885a3e2b186de
Signed-off-by: Spencer Oliver <spen@spen-soft.co.uk>
Reviewed-on: http://openocd.zylin.com/1050
Tested-by: jenkins
50d5441e2a commit added a regression when
using pipes with GDB, OpenOCD would appear to hang when exiting GDB.
This fixes that behaviour so we shutdown correctly.
Change-Id: I9b337c2bdd41b1966de1c7631118257afcbfa6bd
Signed-off-by: Spencer Oliver <spen@spen-soft.co.uk>
Reviewed-on: http://openocd.zylin.com/993
Tested-by: jenkins
Updated as per ST RM0033 rev 5
Change-Id: I627fdab69b440b75b8e4f7c474216538fa5273a4
Signed-off-by: Spencer Oliver <spen@spen-soft.co.uk>
Reviewed-on: http://openocd.zylin.com/1001
Tested-by: jenkins
This is the new proprietary interface replacing the older FTDI based adapters.
It is currently fitted to the ek-lm4f232 and Stellaris LaunchPad.
Change-Id: I794ad79e31ff61ec8e9f49530aca9308025c0b60
Signed-off-by: Spencer Oliver <spen@spen-soft.co.uk>
Reviewed-on: http://openocd.zylin.com/922
Tested-by: jenkins
Other adapters (TI ICDI) that use this driver can use a larger
read/write buffer size than the original stlink could.
Change-Id: I9beb7748049097cbe29a2340799c450bd74e199d
Signed-off-by: Spencer Oliver <spen@spen-soft.co.uk>
Reviewed-on: http://openocd.zylin.com/948
Tested-by: jenkins
Watchpoints were not being enabled when the hl adapter target was resumed.
This effects both stlink and icdi interfaces.
Change-Id: Ia9f8a9415be97a467cd099b63b6bc9f7f37d0c0d
Signed-off-by: Spencer Oliver <spen@spen-soft.co.uk>
Reviewed-on: http://openocd.zylin.com/931
Tested-by: jenkins
Update rtos detection to use the new target name.
Change-Id: I4e55311bcfbc8af55708b43daf0c73b1c8145934
Signed-off-by: Spencer Oliver <spen@spen-soft.co.uk>
Reviewed-on: http://openocd.zylin.com/923
Tested-by: jenkins
As part of the switch to using the hla for the stlink interface we rename
the cmds to a more generic name.
Update scripts to match new names.
Also add handlers for deprecated names.
Change-Id: I6f00743da746e3aa13ce06acfdc93c8049545e07
Signed-off-by: Spencer Oliver <spen@spen-soft.co.uk>
Reviewed-on: http://openocd.zylin.com/921
Tested-by: jenkins
This enables us to change the target name without breaking any
target scripts.
Change-Id: I635f961e573264d3dab2560f3a803ef1986ccfde
Signed-off-by: Spencer Oliver <spen@spen-soft.co.uk>
Reviewed-on: http://openocd.zylin.com/919
Tested-by: jenkins
Print stlink info always rather than just when debug log enabled.
Change-Id: I2a29ef046925200e1c94624280c0b252fab5219a
Signed-off-by: Spencer Oliver <spen@spen-soft.co.uk>
Reviewed-on: http://openocd.zylin.com/925
Tested-by: jenkins
Even though the stlinkv1 and stlinkv2 use different usb classes they share
the same layout scheme.
Merge the two into a common layout, thus enabling us to support other
adapter layouts.
Change-Id: I7d02c44a7f94ebc7f2cb5428b02ee40294fb430d
Signed-off-by: Spencer Oliver <spen@spen-soft.co.uk>
Reviewed-on: http://openocd.zylin.com/918
Tested-by: jenkins
Fix for bug introduced in in mips smp support code
in the resume logic that is checking for wrong return
value.
Change-Id: Ice3e0069f936b556fecc338ccc12ddba38deeaf6
Signed-off-by: Kamal Dasu <kdasu.kdev@gmail.com>
Reviewed-on: http://openocd.zylin.com/1048
Tested-by: jenkins
Reviewed-by: Spencer Oliver <spen@spen-soft.co.uk>
As the other arg checks do not OR, it is assumed this is a copy/paste error
from the original code author.
Change-Id: I7dfc7396254a6f558887def951c57dfd4a0e6c2c
Signed-off-by: Spencer Oliver <spen@spen-soft.co.uk>
Reviewed-on: http://openocd.zylin.com/997
Tested-by: jenkins
Reviewed-by: Paul Fertser <fercerpav@gmail.com>
Reviewed-by: Freddie Chopin <freddie.chopin@gmail.com>
Currently if the target supports srst_nogate we wait until target assert_reset
until we get a chance to assert the srst.
However sometimes we will not get this far if the target has already failed
the initial scan.
This has been tested on stm32.
Change-Id: I2c4486942a011534d3e2044788563669bf457b60
Signed-off-by: Spencer Oliver <spen@spen-soft.co.uk>
Reviewed-on: http://openocd.zylin.com/972
Reviewed-by: Paul Fertser <fercerpav@gmail.com>
Tested-by: jenkins
Reviewed-by: Freddie Chopin <freddie.chopin@gmail.com>
Currently if the target supports srst_nogate we wait until target assert_reset
until we get a chance to assert the srst.
However sometimes we will not get this far if the target has already failed
the jtag_examine_chain.
This has been tested on targets that support this behaviour (STM32 and STR9).
Change-Id: Ibcf7584b137b472f31ba6ddd5cd99d848c5508d1
Signed-off-by: Spencer Oliver <spen@spen-soft.co.uk>
Reviewed-on: http://openocd.zylin.com/971
Tested-by: jenkins
Reviewed-by: Paul Fertser <fercerpav@gmail.com>
Reviewed-by: Freddie Chopin <freddie.chopin@gmail.com>
This adds the ability to request to the adapter how we want to connect to
the target, eg. while srst is asserted or not.
This ability can very handy for connecting to unresponsive targets.
A prerequisite is that the target supports srst_nogate.
Change-Id: I0f7c9475160048e8a963e16077754f5403ac8325
Signed-off-by: Spencer Oliver <spen@spen-soft.co.uk>
Reviewed-on: http://openocd.zylin.com/976
Reviewed-by: Paul Fertser <fercerpav@gmail.com>
Tested-by: jenkins
Reviewed-by: Freddie Chopin <freddie.chopin@gmail.com>
If target is disabled at init, then is examined using 'arp_examine', it
can get to cortex_a8_poll with the target state being unknown.
Change-Id: Ifffb345bf971d275d2eb1912648b29f0a75f6ccc
Signed-off-by: Evan Hunter <ehunter@broadcom.com>
Reviewed-on: http://openocd.zylin.com/954
Tested-by: jenkins
Reviewed-by: Spencer Oliver <spen@spen-soft.co.uk>