pluto_hdl_adi/projects/fmcjesdadc1/common
Lars-Peter Clausen 8b6d69747b fmcjesdadc1: Fix OUT_CLK_SEL configuration
The script specifies the OUT_CLK_SEL and SYS_CLK_SEL parameter values as
binary numbers. But the tools will interpret them as decimal number
resulting in the wrong selection for OUT_CLK_SEL. Specify the parameter
values as decimal values to avoid this.

This is not a critical issue since software will overwrite this setting at
system boot-up. But it should be fixed anyway.

Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
2018-02-16 13:32:50 +01:00
..
fmcjesdadc1_bd.tcl fmcjesdadc1: Fix OUT_CLK_SEL configuration 2018-02-16 13:32:50 +01:00
fmcjesdadc1_qsys.tcl fmcjesdadc1: Update A10GX/A10SOC projects to the ADI JESD framework 2017-11-08 14:35:18 +02:00
fmcjesdadc1_spi.v license: Add some clarification to the header license 2017-05-31 18:18:56 +03:00