This feature will allow the user to hold(indefinitely) the last sample, from an
ongoing DMA transfer, simple or cyclic(stooped by user or trigger).
This commit also adds as functionality option:
-synchronized stop between the two channels(DMAs)
-stop by trigger
Also modified the FIFO ports to have the same widths so that in a
future commit the bypass would be available for cases when the
sampling rate won't be the maximum rate or the number of channels
active will be less than maximum number of channels
This reverts commit 0402ce85e4
and reverts commit 164aa97ec3.
The trigger pulse generation must be handled outside of the
SPI Engine framework.
It is recommanded to be done in system level using a PWM
generator or an external signal.
Switch RX path reset to be controlled by the TPL and use
RX SYSREF as external synchronization for the ADC TPL
Use TX SYSREF for synchornizing the TX DDS
The device clocks are AC coupled LVDS lines without external termination.
For proper operation internal differential termination must be enabled,
the DQS_BIAS will DC bias the AC coupled signal to VCCO/2 (1.8/2) 0.9V
Added reference design for the ad9656 evaluation board coupled with the
zcu102 carrier board. The JESD204 communication link that transfers data
from the 4 ADCs to the FPGA has the following paramenters : L=4, M=4, S=1,
F=2, HD=0, N=16, NP=16. The JESD204 line rate is configured to be 2.5GHz.
Signed-off-by: Dan Hotoleanu <dan.hotoleanu@analog.com>
The coraz7s has an Arduino/chipKIT Shield connector with 6 Single-ended
and 8 Differential Analog inputs tied to Xilinx's XADC.
The CN0540 uses the A0-5 pins as single-ended ADC channels to monitor
the differential input, ADC driver, and buffer voltages.
Signed-off-by: Sergiu Cuciurean <sergiu.cuciurean@analog.com>
Note, the current SCLK to spi_clk ratio is four. That means, the input
delay in the MISO line is 25% of the SCLK period.
If the SCLK to spi_clk ratio is changing, this constraint must be
updated.
Generate a higher frequency of spi_clk using an axi_clkgen. (MMCM)
CAUTION: ad7768-1 is still violating the standard SPI timing,
reducing the timing window significantly for the last bit (or last high
bit).
fixed critical warnings generated when the NUM_OF_CLK_MONS parameter
is set to 0 and the constraints written in up_clock_mon_constr.xdc
cannot be applied; removed up_clock_mon_constr.xdc from ip core.
When the link is disabled the events can be ignored.
This is required by the free running event counter that can catch
invalid events during startup cased for example by an invalid link clock.
If the lane looses synchronization due invalid characters or disparity
error the lane alignment monitor checks random input which results in
irrelevant reporting of frame alignment error.