This patch will fix the following critical warning, generated by Quartus:
"Critical Warning (18061): Ignored Power-Up Level option on the following
registers
Critical Warning (18010): Register ad_rst:i_core_rst_reg|rst_sync will power
up to High File: ad_rst.v Line: 50"
For a proper reset synchronization, the asynchronous reset signal should
be connected to the reset pins of the two synchronizer flop, and the
data input of the first flop should be connected to VCC.
In the first stage we're synchronizing just the reset de-assertion, avoiding
the scenario when different parts of the design are reseting at different time,
causing unwanted behaviours.
In the second stage we're synchronizing the reset assertion.
The module expects an ACTIVE_HIGH input reset signal, and provides an ACTIVE_LOW
(rstn) and an ACTIVE_HIGH (rst) synchronized reset output signal.
Just one VCC or GND xlconstant will be generated for each width. This
way we can avoid having a lot of xlconstant instances with the same
configuration.
Assign a unique value to each lane's error count register and verify that
the correct value is returned for the right lane.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
The RX register map testbench currently fails because the expected value
for the version register was not updated, when the version was incremented.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
The loopback testbench currently fails, because the cfg_links_disable signal is not connected to the RX side of the link.
Fix this.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
In case when the SYSREF is connected to an FPGA IO which has a limitation
on the IOB register IN_FF clock line and the required ref clock is high
we can't use the IOB registers.
e.g. the max clock rate on zcu102 HP IO FF is 312MHz but ref clock is 375MHz;
If IOB is used in this case a pulse width violation is reported.
This change makes the IOB placement selectable in such case or
for targets which don't require class 1 operation.
The round function from tcl is a rounding to nearest. Using it in address
width calculation produces incorrect values.
e.g.
round(log(0xAF000000)/log(2)) will produce 31 instead of 32
The fix is to replace the rounding function with ceiling that guarantees
rounding up.
- remove reset logic
- add wait for dac valid logic
- rewrite sine concatenation on wires for different path width to
suppress warnings
- use computed atan LUT tables
The CORDIC has a selectable width range for phase and data of 8-24.
Regarding the width of phase and data, the wider they are the smaller
the precision loss when shifting but with the cost of more FPGA
utilization. The user must decide between precision and utilization.
The DDS_WD parameter is independent of CORDIC(CORDIC_DW) or
Polynomial(16bit), letting the user chose the output width.
Here we encounter two scenarios:
* DDS_DW < DDS data width - in this case, a fair rounding will be
implemented corresponding to the truncated bits
* DDS_DW > DDS data width - DDS out data left shift to get the
corresponding concatenation bits.
Update for the parametrized ad_mul module. This will scale
a selectable sine width in a multiplication module.
Rename the data and phase width parameters for legibility.
When the tool calculates the X value for different phase widths, we
get rounding errors for every width in the interval [8;24].
Depending on the width thess errors cause overflows or smaller amplitudes
of the sine waves.
The error is not linear nor proportional with the phase. To fix the issue
a simple aproximation was chosen.
Perform the shifting operation before addition/subtraction in a
rotation stage. In the previous method, the result of the arithmetic
operation was shifted and the outcome was presented to the next stage.
In this way, data connections will be reduced between pipeline stages