The extra delay was added on the trigger and data paths to compensate
for the logic analyzer changes.
The extra delay will be also seen on the m2k daisy chain. The
delay between devices will be increased from 3 to 4 samples delay.
Fix external trigger for low sampling rates.
Because the external trigger can be a short pulse at high decimation rates
there is a high chance that the pulse will be missed.
xsim does not like if a register or wire is used before their
definition. Make sure the every register and wire is defined before it's
used the first time.
The second ADC was removed from the project, as the EV-AD7768-1FMCZ evaluation
board contains only one ADC. Therefore, all the IPs related to the
second ADC have been removed, too.
The data width supported by the spi IPs has been changed from 8 bits to
32 bits, therefore the axis_upscaler(util_axis_upscale_v1_0) and the
m_axis_samples_24(AXI4-Stream Data Width Converter) are no more necessary,
so they have been removed from the design.
The 24 bits width data transfer between the s_axis of axi_ad77681_dma
(AXI DMA Controller) and the offload_sdi of the spi_engine_offload is now made
directly.
Add commands to generate one extra file with resource utilization, in CSV format.
New commands executes only if ADI_GENERATE_UTILIZATION env variable is set.
In ZCU102 LA01_CC_P|N are connected to regional clock, but in order to
receive a device clock properly we have to use pin which is connected
to a global clock buffer. Luckily SYSREF is connected to global clock
pin; swap to port to receive the device clock correctly.
Also, swap the ports in both ZC706 and A10SOC carriers.
mclk now generated by ps not axi clkgen ip. ADAU1761 expects a free
running clock and the i2s driver was switching the axi clkgen ip off
which was causing issues.
In Subclass 1 mode, we need to use a separate clock (device clock) to
drive the link and transport layer of the interface. Implement the
required infrastructure for this scenario.
The clock domain crossing will be done in by the TX|RX_FIFO in the PCS.
In Subclass 1 mode an external device clock (core clock) is used,
instead of the PCS output clock, to drive the link and transport layer.
Define an additional parameter, which can be used to enable clock input
port for the PHY module, which can be used as rx|tx_coreclkin source.
This commit reverts part of the changes done in the following commit:
- ff50963c7f -
"axi_ad9361- altera/xilinx reconcile- may be broken- do not use"
The above mentioned commit introduced latency variations on the Rx path
at different sample rates, or within the same sample rate after sample
rate changes. The variation is caused by multiple positions of the frame
detection combined with a free running toggle (rx_valid) that is not synchronized
with the actual samples.
Having a single frame detection position eliminates the latency
variation.
When having multiple 936x in parallel, this change enables the use of source
synchronous received clock from the master as sampling clock for other slaves.
This will eliminate skew between the interfaces since the data delays
are going to be tuned against the master clock after a multi-chip
synchronization (MCS) is done. This eliminates the clock crossing from
the slave to master domain inside the FPGA.