adrv9009zu11eg & common/zcu102 : Fix zynqmp ref clock definition
The derived clocks of the zynqmp core are not calculated correctly due rounding issues, instead of 100MHz the value of 99999001 is received causing warnings during system validation. This can be fixed/worked around with the proper reference clock definition.main
parent
b354d517f5
commit
b7f34f7bd9
|
@ -23,6 +23,7 @@ create_bd_port -dir I dac_fifo_bypass
|
|||
|
||||
ad_ip_instance zynq_ultra_ps_e sys_ps8
|
||||
|
||||
ad_ip_parameter sys_ps8 CONFIG.PSU__PSS_REF_CLK__FREQMHZ 33.333333333
|
||||
ad_ip_parameter sys_ps8 CONFIG.PSU__USE__M_AXI_GP0 0
|
||||
ad_ip_parameter sys_ps8 CONFIG.PSU__USE__M_AXI_GP1 0
|
||||
ad_ip_parameter sys_ps8 CONFIG.PSU__USE__M_AXI_GP2 1
|
||||
|
|
|
@ -22,6 +22,7 @@ ad_ip_instance zynq_ultra_ps_e sys_ps8
|
|||
apply_bd_automation -rule xilinx.com:bd_rule:zynq_ultra_ps_e \
|
||||
-config {apply_board_preset 1} [get_bd_cells sys_ps8]
|
||||
|
||||
ad_ip_parameter sys_ps8 CONFIG.PSU__PSS_REF_CLK__FREQMHZ 33.333333333
|
||||
ad_ip_parameter sys_ps8 CONFIG.PSU__USE__M_AXI_GP0 0
|
||||
ad_ip_parameter sys_ps8 CONFIG.PSU__USE__M_AXI_GP1 0
|
||||
ad_ip_parameter sys_ps8 CONFIG.PSU__USE__M_AXI_GP2 1
|
||||
|
|