## This file contains all the message severity changes for Vivado 20xx.x.x
|
||
|
## These should reviewed at each release and updated if necessary
|
||
|
|
||
|
## A MUST: Every severity change must have a well defined and described role
|
||
|
## or purpose, and contains the instance of the original message. The main target
|
||
|
## here is to clean the log file from invalid CRITICAL WARNINGS.
|
||
|
##
|
||
|
## User should never change a CRITICAL WARNING to INFO, just to WARNING!
|
||
|
|
||
|
## This file is source in two places:
|
||
|
#
|
||
|
## at ~/hdl/library/scripts/adi_ip.tcl
|
||
|
## and
|
||
|
## at ~/hdl/projects/scripts/adi_project.tcl
|
||
|
##
|
||
|
################################################################################
|
||
|
|
||
|
################################################################################
|
||
|
## Block Design related messages
|
||
|
## IDs : [BD 41-xxxx]
|
||
|
################################################################################
|
||
|
|
||
|
## Temporally disabled - could not find and message with this ID
|
||
|
## set_msg_config -id {BD 41-1348} -new_severity WARNING
|
||
|
|
||
|
## Reset pin A (associated clock X) is connected to reset source B (associated
|
||
|
## clock Y) -- this is a reset transfer between two clock domain, it should stay
|
||
|
## CRITICAL -- needs to be reviewed
|
||
|
set_msg_config -id {BD 41-1343} -new_severity WARNING
|
||
|
|
||
|
## The connection to interface pin A is being overridden by the user. This pin
|
||
|
## will not be connected as a part of interface connection B (pin A is part of
|
||
|
## the B interface)
|
||
|
## In the future this should disappear, as we switch to using mostly interfaces
|
||
|
set_msg_config -id {BD 41-1306} -new_severity WARNING
|
||
|
|
||
|
## Cannot set the parameter XXXXXX. It is read-only. | Parameter does not exist.
|
||
|
## To make sure that each and every IP is configured correctly we push this
|
||
|
## CRITICAL WARNING into the ERRORs domain.
|
||
|
set_msg_config -severity {CRITICAL WARNING} -quiet -id {BD 41-1276} -new_severity ERROR
|
||
|
|
||
|
################################################################################
|
||
|
## IP packaging and flow related messages [IP_Flow xx-xxxx]
|
||
|
## IDs : [IP_Flow 19-xxxx]
|
||
|
################################################################################
|
||
|
|
||
|
## Temporally disabled - could not find and message with this ID
|
||
|
## set_msg_config -id {IP_Flow 19-1687} -new_severity WARNING
|
||
|
|
||
|
## If you move the project, the path for repository '~/hdl/library' may become
|
||
|
## invalid. A better location for the repository would be in a path adjacent to
|
||
|
## the project. -- Vivado does not like when library sources are outside the project
|
||
|
## directory.
|
||
|
set_msg_config -id {IP_Flow 19-3656} -new_severity INFO
|
||
|
|
||
|
## Temporally disabled - could not find and message with this ID
|
||
|
## set_msg_config -id {IP_Flow 19-2999} -new_severity INFO
|
||
|
|
||
|
## Temporally disabled - could not find and message with this ID
|
||
|
## set_msg_config -id {IP_Flow 19-1654} -new_severity INFO
|
||
|
|
||
|
## Unrecognized family xxxxxxx. Please verify spelling and reissue command to
|
||
|
## set the supported files. -- the adi_ip.tcl script trying to add all the existent
|
||
|
## family to the supported family list. Apparently Xilinx has some inconsistent
|
||
|
## naming conventions for families. TODO:Maybe we should define exactly the supported
|
||
|
## architectures.
|
||
|
set_msg_config -id {IP_Flow 19-4623} -new_severity INFO
|
||
|
|
||
|
## IP file '~/hdl/library/common/xxxx.v' appears to be outside of the project area.
|
||
|
## This is similar to 19-3656
|
||
|
set_msg_config -id {IP_Flow 19-459} -new_severity INFO
|
||
|
|
||
|
## Temporally disabled - could not find and message with this ID
|
||
|
## set_msg_config -id {filemgmt 20-1763} -new_severity WARNING
|
||
|
|
||
|
################################################################################
|
||
|
## Placer related messages
|
||
|
## IDs : [Place 30-xxxx]
|
||
|
################################################################################
|
||
|
|
||
|
## Invalid constraint on register */axi_spi/*/IOx_I_REG. It has the property IOB=TRUE,
|
||
|
## but is is not driving or driven by any IO element. -- The AXI_SPI IP after
|
||
|
## 2017.4 has a default constraint which setting the input registers property
|
||
|
## IOB=TRUE, this will cause a CRITICAL WARNING is the interface is not used.
|
||
|
set_msg_config -id {Place 30-73} -string "axi_spi" -new_severity WARNING
|
||
|
|
||
|
################################################################################
|
||
|
## Other ID less messages
|
||
|
################################################################################
|
||
|
|
||
|
## After Vivado 2017.4, the tool does not like negative DDR_DQS_TO_CLK_DELAY
|
||
|
## values on the DDRx interface, and throw a CRITICAL WARNING. Although a negative
|
||
|
## value is not necessarily invalid, the ZedBoard's interface is working this way.
|
||
|
set_msg_config -string "PCW_UIPARAM_DDR_DQS_TO_CLK_DELAY" -new_severity WARNING
|
||
|
|